1
GATE EE 2003
MCQ (Single Correct Answer)
+2
-0.6
A list of relays and the power system components protected by the relays are given in List-$${\rm I}$$ and List-$${\rm II}$$ respectively. Choose the correct match from the four choices given below

List-$${\rm I}$$
$$A.$$ Distance relay
$$B.$$ Under frequency relay
$$C.$$ Differential relay
$$D.$$ Buchholz relay

List-$${\rm II}$$
$$1.$$ Transformers
$$2.$$ Turbines
$$3.$$ Busbars
$$4.$$ Shunt capacitors
$$5.$$ Alternators
$$6.$$ Transmission lines

A
$$A = 6,\,B = 5,\,C = 3,\,D = 1$$
B
$$A = 4,\,B = 3,\,C = 2,\,D = 1$$
C
$$A = 5,\,B = 2,\,C = 1,\,D = 6$$
D
$$A = 6,\,B = 4,\,C = 5,\,D = 3$$
2
GATE EE 2003
MCQ (Single Correct Answer)
+1
-0.3
The interrupting time of a circuit breaker is the period between the instant of
A
Initiation of short circuit and the arc extinction on an opening operation
B
Energizing of the trip circuit and the arc extinction on an opening operation
C
Initiation of short circuit and the parting of primary arc contacts
D
Energizing of the trip circuit and the parting of primary arc contacts
3
GATE EE 2003
MCQ (Single Correct Answer)
+2
-0.6
A three-phase alternator generating unbalanced voltages is connected to an unbalanced load through a 3-phase transmission line as shown in figure. The neutral of the alternator and the star point of the load are solidly grounded. The phase voltages of the alternator are
$${E_a} = 10\angle {0^ \circ }V,\,\,\,{E_b} = 10\angle - {90^ \circ }V,\,\,{E_c} = 10\angle {120^ \circ }\,\,V.\,\,\,\,$$ The positive sequence component of the load current is GATE EE 2003 Power System Analysis - Symmetrical Components and Symmetrical and Unsymmetrical Faults Question 28 English
A
$$1.310\angle - {107^ \circ }A\,$$
B
$$0.332\angle - {120^ \circ }A\,$$
C
$$0.996\angle - {120^ \circ }A\,$$
D
$$3.510\angle - {81^ \circ }A\,$$
4
GATE EE 2003
MCQ (Single Correct Answer)
+2
-0.6
A 20-MVA, 6.6-kV, 3-phase alternator is connected to a 3-phase transmission line. The per unit positive sequence, negative sequence and zero sequence impedance of the alternator are j0.1, and j0.04 respectively. The neutral of the alternator is connected to ground through an inductive reactor of j0.05 p.u. The per unit positive, negative and zero sequence impedances of the transmission line are j0.1 and j0.3 respectively. All per unit values are based on the machine ratings. A solid ground fault occurs at one phase of the far end of the transmission line. The voltage of the alternator neutral with respect to ground during the fault is
A
513.8 V
B
889.9 V
C
1112.0 V
D
642.2 V