1
GATE EE 2003
MCQ (Single Correct Answer)
+2
-0.6
A $$4$$-pole, $$3$$-phase, double layer winding is housed in a $$36$$-slot stator for an $$ac$$ machine with $$60$$ degree phase spread. Coil span is $$7$$ slot pitches. Number of slots in which top and bottom layers belong to different phases is.
A
$$24$$
B
$$18$$
C
$$12$$
D
$$0$$
2
GATE EE 2003
MCQ (Single Correct Answer)
+2
-0.6
When Stator and Rotor windings of a 2-pole rotating electrical machine are excited, each would produce a sinusoidal mmf distribution in the air gap with peak values Fs and Fr respectively. The rotor mmf lags stator mmf by a space angle $$\delta\;$$ at any instant as shown in Fig. Thus, half of stator and rotor surfaces will form one pole with the other half forming the second pole. Further, the direction of torque acting on the rotor can be clockwise or counter-clockwise. GATE EE 2003 Electrical Machines - Induction Machines Question 49 English The following Table gives four sets of statements as regards poles and torque. Select the correct set corresponding to the mmf axes as shown in Figure.
A
Stator
Surface
ABC
forms
Stator
Surface
CDA
forms
Rotor
Surface
abc
forms
Rotor
Surface
cda
forms
Torque
North
Pole
South
Pole
North
Pole
South
Pole
Clock
wise
B
Stator
Surface
ABC
forms
Stator
Surface
CDA
forms
Rotor
Surface
abc
forms
Rotor
Surface
cda
forms
Torque
South
Pole
North
Pole
North
Pole
South
Pole

Counter
Clock
wise
C
Stator
Surface
ABC
forms
Stator
Surface
CDA
forms
Rotor
Surface
abc
forms
Rotor
Surface
cda
forms
Torque
North
Pole
South
Pole
South
Pole

North
Pole

Counter
Clock
wise
D
Stator
Surface
ABC
forms
Stator
Surface
CDA
forms
Rotor
Surface
abc
forms
Rotor
Surface
cda
forms
Torque
South
Pole
North
Pole
South
Pole
North
Pole
Clock
wise
3
GATE EE 2003
MCQ (Single Correct Answer)
+1
-0.3
A stand-alone engine driven Synchronous generator is feeding a partly inductive load. A capacitor is now connected across the load to completely nullify the inductive current. For this operating condition.
A
the field current and fuel input have to be reduced
B
the field current and fuel input have to be increased
C
the field current has to be increased and fuel input left unaltered
D
the field current has to be reduced and fuel input left unaltered
4
GATE EE 2003
MCQ (Single Correct Answer)
+1
-0.3
Curves X and Y in Figure denote open circuit and full-load zero power factor (zpf) characteristics of asynchronous generator. Q is a point on the zpf characteristics at 1.0 p.u. voltage. The vertical distance PQ in Figure gives the voltage drop across GATE EE 2003 Electrical Machines - Synchronous Machines Question 71 English
A
Synchronous reactance
B
Magnetizing reactance
C
Potier reactance
D
Leakage reactance
EXAM MAP
Medical
NEETAIIMS
Graduate Aptitude Test in Engineering
GATE CSEGATE ECEGATE EEGATE MEGATE CEGATE PIGATE IN
Civil Services
UPSC Civil Service
Defence
NDA
Staff Selection Commission
SSC CGL Tier I
CBSE
Class 12