1
GATE EE 2005
MCQ (Single Correct Answer)
+2
-0.6
The parameters of transposed overhead transmission line are given as: self reactance $${X_s} = 0.4\,\,\Omega /km$$ and Mutual reactance $$\,{X_m} = 0.1\,\,\Omega /km.\,\,$$ The positive sequence reactance $${X_1}$$ and zero sequence reactance $${X_0}$$ respectively in $$\Omega /km$$ are
A
$$0.3, 0.2$$
B
$$0.5, 0.2$$
C
$$0.5, 0.6$$
D
$$0.3, 0.6$$
2
GATE EE 2005
MCQ (Single Correct Answer)
+2
-0.6
The network shown in the given figure has impedances in p.u. as indicated. The diagonal element $$Y22$$ of the bus admittance matrix $${Y_{BUS}}$$ of the network is GATE EE 2005 Power System Analysis - Load Flow Studies Question 22 English
A
$$-j$$ $$19.8$$
B
$$+j$$ $$20.0$$
C
$$+j$$ $$0.2$$
D
$$-j$$ $$19.95$$
3
GATE EE 2005
MCQ (Single Correct Answer)
+1
-0.3
The insulation strength of an EHV transmission line is mainly governed by
A
Load power factor
B
Switching over-voltages
C
Harmonics
D
Corona
4
GATE EE 2005
MCQ (Single Correct Answer)
+2
-0.6
A load centre is at an equidistant from the two thermal generating stations $${G_1}$$ and $${G_2}$$ as shown in figure. The fuel cost characteristics of the generating stations are given by
$${F_1} = a + b{P_1} + cP_1^2\,Rs/hour$$
$${F_2} = a + b{P_2} + 2cP_2^2\,Rs/hour$$ GATE EE 2005 Power System Analysis - Power Generation Cost Question 15 English

Where $${P_1}$$ and $${P_2}$$ are the generations in $$MW$$ of $${G_1}$$and $${G_2}$$, respectively. For most economic generation to meet $$300MW$$ of load $${P_1}$$ and $${P_2},$$ respectively, are

A
$$150, 150$$
B
$$100, 200$$
C
$$200, 100$$
D
$$175, 125$$