1
GATE EE 2011
MCQ (Single Correct Answer)
+1
-0.3
A nuclear power station of $$500$$ $$MW$$ capacity is located at $$300$$ km away from a load center. Select the most suitable power evacuation transmission configuration among the following options.
A
GATE EE 2011 Power System Analysis - Parameters and Performance of Transmission Lines Question 70 English Option 1
B
GATE EE 2011 Power System Analysis - Parameters and Performance of Transmission Lines Question 70 English Option 2
C
GATE EE 2011 Power System Analysis - Parameters and Performance of Transmission Lines Question 70 English Option 3
D
GATE EE 2011 Power System Analysis - Parameters and Performance of Transmission Lines Question 70 English Option 4
2
GATE EE 2011
MCQ (Single Correct Answer)
+2
-0.6
A three–bus network is shown in the figure below indicating the p.u. impedances of each element GATE EE 2011 Power System Analysis - Load Flow Studies Question 17 English

The bus admittance matrix, $$Y$$-$$bus,$$ of the network is

A
$$j\left[ {\matrix{ {0.3} & { - 0.2} & 0 \cr { - 0.2} & {0.12} & {0.08} \cr 0 & {0.08} & {0.02} \cr } } \right]$$
B
$$j\left[ {\matrix{ { - 15} & 5 & 0 \cr 5 & {7.5} & { - 12.5} \cr 0 & { - 12.5} & {2.5} \cr } } \right]$$
C
$$j\left[ {\matrix{ {0.1} & {0.2} & 0 \cr {0.2} & {0.12} & { - 0.08} \cr 0 & { - 0.08} & {0.10} \cr } } \right]$$
D
$$j\left[ {\matrix{ { - 10} & 5 & 0 \cr 5 & {7.5} & {12.5} \cr 0 & {12.5} & { - 10} \cr } } \right]$$
3
GATE EE 2011
MCQ (Single Correct Answer)
+1
-0.3
A negative sequence relay is commonly used to protect
A
An alternator
B
A transformer
C
A transmission line
D
A bus bar
4
GATE EE 2011
MCQ (Single Correct Answer)
+2
-0.6
Two generator units $$G1$$ and $$G2$$ are connected by $$15$$ $$kV$$ line with a bus at the mid-point as shown below GATE EE 2011 Power System Analysis - Per Unit System Question 5 English
$${G_1} = 250\,\,MVA.\,\,\,15kV,\,\,$$ positive sequence $$X = 25$$% on its own base
$${G_2} = 100\,\,MVA.\,\,\,15kV,\,$$ positive sequence $$X = 10$$% on its own base
$${L_1}$$ and $${L_2}$$ $$= 10$$ $$km,$$ positive sequence $$ X = 0.225$$ $$\,\,\Omega /km$$

For the above system, the positive sequence diagram with the p.u values on the $$100$$ $$MVA$$ common

A
GATE EE 2011 Power System Analysis - Per Unit System Question 5 English Option 1
B
GATE EE 2011 Power System Analysis - Per Unit System Question 5 English Option 2
C
GATE EE 2011 Power System Analysis - Per Unit System Question 5 English Option 3
D
GATE EE 2011 Power System Analysis - Per Unit System Question 5 English Option 4