1
GATE EE 1999
MCQ (Single Correct Answer)
+1
-0.3
The following starting method for an induction motor is inferior view of the poor starting torque per ampere of the line current drawn:
A
Direct line starting
B
Auto transformer method of starting
C
Series inductor method of starting
D
Star-Delta method of starting
2
GATE EE 1999
MCQ (Single Correct Answer)
+1
-0.3
Higher synchronous reactance is preferred in the present day alternators, because one can have
A
reduced sub-transient currents
B
reduced harmonic currents
C
reduced transient currents
D
higher voltage regulation with load
3
GATE EE 1999
MCQ (Single Correct Answer)
+2
-0.6
A three phase alternator is wound with a 60 degree phase-spread armature windings and develops 300 kVA. If the armature is reconnected utilizing all the coils for single phase operation with a phase spread of 180 degrees, the new rating of the machine is
A
100 kVA
B
200 kVA
C
250 kVA
D
300 kVA
4
GATE EE 1999
Subjective
+5
-0
A separately excited $$DC$$ shunt motor is driving a fan load whose torque is proportional to the square of the speed. When $$100$$ $$V$$ are applied to the motor, the current taken by the motor is $$8$$ $$A,$$ with the speed being $$500$$ $$rpm.$$ At what applied voltage does the speed reach $$750$$ $$rpm$$ and then what is the current drawn by the armature? Assume the armature circuit resistance to be $$1\,\,\,\Omega .$$ Neglect brush drop and mechanical losses.