1
GATE CE 2017 Set 1
MCQ (Single Correct Answer)
+2
-0.6
A planar truss tower structure is shown in the figure:
GATE CE 2017 Set 1 Structural Analysis - Stability and Static Indeterminacy Question 10 English Consider the following statements about the external and internal determinacies of the truss.
(P) Externally Determinate
(Q) External Static Indeterminacy = 1
(R) External Static Indeterminacy = 2
(S) Internally Determinate
(T) Internal Static Indeterminacy = 1
(U) Internal Static Indeterminacy = 2
Which one of the following options is correct?
A
P-False; Q-True; R-False; S-False; T-False; U-True
B
P-False; Q-True; R-False; S-False; T-False; U-False
C
P-False; Q-False; R-True; S-False; T-False; U-True
D
P-True; Q-True; R-False; S-True; T-False; U-True
2
GATE CE 2009
MCQ (Single Correct Answer)
+2
-0.6
The degree of static indeterminacy of a rigidly jointed frame in a horizontal plane and subjected to vertical loads only, as shown in figure below is GATE CE 2009 Structural Analysis - Stability and Static Indeterminacy Question 11 English
A
6
B
4
C
3
D
1
3
GATE CE 2008
MCQ (Single Correct Answer)
+2
-0.6
The degree of static indeterminacy of the rigid frame having two internal hinges as shown in the figure below, is GATE CE 2008 Structural Analysis - Stability and Static Indeterminacy Question 12 English
A
8
B
7
C
6
D
5
4
GATE CE 1993
MCQ (Single Correct Answer)
+2
-0.6
The plane figure shown below is GATE CE 1993 Structural Analysis - Stability and Static Indeterminacy Question 3 English
A
stable and statically determinate
B
unstable and statically determinate
C
stable and statically indeterminate
D
unstable and statically indeterminate