1
GATE CE 2000
Subjective
+5
-0
A continuous beam $$250\,mm \times 450\,mm$$ carries $$6$$ numbers of $$12$$ $$mm$$ diameter longitudinal bars as shown. The factored shear force at the point of inflection is $$200$$ $$kN.$$ Check if the beam is safe in bond. Assume $$M15$$ mix with $${\sigma _{ck}} = 15\,\,N/m{m^2}$$ and mild steel with $${\sigma _y} = 250\,N/m{m^2}.$$ A clear cover of $$25$$ $$mm$$ can be assumed. The design bond stress for mild steel bars in $$M15$$ concrete is specified to be $$1.0\,N/m{m^2}.$$
Questions Asked from Bond (Marks 5)
Number in Brackets after Paper Indicates No. of Questions
GATE CE Subjects
Engineering Mechanics
Strength of Materials Or Solid Mechanics
Structural Analysis
Construction Material and Management
Reinforced Cement Concrete
Steel Structures
Geotechnical Engineering
Fluid Mechanics and Hydraulic Machines
Geomatics Engineering Or Surveying
Environmental Engineering
Transportation Engineering
Engineering Mathematics
General Aptitude