1
GATE EE 2007
MCQ (Single Correct Answer)
+2
-0.6
A single-phase $$50$$ $$kVA,$$ $$250$$ $$V/500V$$ two winding transformer has an efficiency of $$95\% $$ at full load, unity power factor. If it is reconfigured as a $$500V/750V$$ auto-transformer, its efficiency at its new rated load at unity power factor will be
A
$$95.752\% $$
B
$$97.851\% $$
C
$$98.276\% $$
D
$$99.241\% $$
2
GATE EE 2007
MCQ (Single Correct Answer)
+1
-0.3
In a transformer, zero voltage regulation at full load is
A
not possible
B
possible at unity power factor load
C
possible at leading power factor load
D
possible at lagging power factor load
3
GATE EE 2007
MCQ (Single Correct Answer)
+1
-0.3
The dc motor, which can provide zero speed regulation at full load without any controller is
A
series
B
shunt
C
cumulative compound
D
differential compound
4
GATE EE 2007
MCQ (Single Correct Answer)
+2
-0.6
An inductor designed with $$400$$ turns coil wound on an iron core of $$16\,\,c{m^2}$$ cross sectional area and with a cut of an air gap length of $$1$$ $$mm$$. The coil is connected to a $$230$$ $$V,$$ $$50$$ $$Hz$$ ac supply. Neglect coil resistance, core loss, iron reluctance and leakage inductance. $$\left( {{\mu _0} = 4\pi \times {{10}^{ - 7}}\,H/m} \right)$$

The average force on the core to reduce the air gap will be

A
$$832.29$$ $$N$$
B
$$1666.22$$ $$N$$
C
$$3332.47$$ $$N$$
D
$$6664.84$$ $$N$$
EXAM MAP
Medical
NEETAIIMS
Graduate Aptitude Test in Engineering
GATE CSEGATE ECEGATE EEGATE MEGATE CEGATE PIGATE IN
Civil Services
UPSC Civil Service
Defence
NDA
Staff Selection Commission
SSC CGL Tier I
CBSE
Class 12