GATE EE 2017 Set 1
MCQ (Single Correct Answer)
+2
-0.6
The load shown in the figure is supplied by a $$400$$ $$V$$ (line-to-line) $$3$$-phase source ($$RYB$$ sequence). The load is balanced and inductive, drawing $$3464$$ $$VA.$$ When the switch $$S$$ is in position $$N$$, the three watt-meters $${W_1},\,{W_2}$$ and $${W_3}$$ read $$577.35$$ $$W$$ each. If the switch is moved to position $$Y,$$ the readings of the watt-meters in watts will be: GATE EE 2017 Set 1 Electrical and Electronics Measurement - Measurement of Energy and Power Question 6 English
A
$${W_1} = 1732\,\,\,$$ and $$\,\,{W_2} = {W_3} = 0$$
B
$${W_1} = 0,\,\,{W_2} = 1732\,\,\,$$ and $$\,\,\,{W_3} = 0$$
C
$${W_1} = 866,\,\,{W_2} = 0,\,\,\,{W_3} = 866$$
D
$${W_1} = {W_2} = 0$$ and $${W_3} = 1732$$
2
GATE EE 2017 Set 1
Numerical
+1
-0
The following measurements are obtained on a single phase load: $$V = 220 V$$ $$ \pm $$$$1$$%. $${\rm I}$$$$= 5.0$$ $$A$$ $$ \pm \,1$$% and $$W=555$$ $$W$$ $$ \pm \,2$$%. If the power factor is calculated using these measurements, the worst case error in the calculated power factor in percent is _________. (Give answer up to one decimal place.)
Your input ____
3
GATE EE 2017 Set 1
Numerical
+2
-0
Two parallel connected, three-phase, $$50Hz,$$ $$11kV,$$ star-connected synchronous machines $$A$$ and $$B,$$ are operating as synchronous condensers. They together supply $$50$$ $$MVAR$$ to a $$11$$ $$kV$$ grid. Current supplied by both the machines are equal. Synchronous reactances of machine $$A$$ and machine $$B$$ are $$1\,\,\Omega $$ and $$3\,\,\Omega ,$$ respectively. Assuming the magnetic circuit to be linear, the ratio of excitation current of machine $$A$$ to that of machine $$B$$ is ____________. (Give the answer up to two decimal places).
Your input ____
4
GATE EE 2017 Set 1
Numerical
+2
-0
A three-phase, three winding $$\triangle$$ / $$\triangle$$ / Y (1.1 kV/6.6 kV/400 V) transformer is energized from AC mains at the 1.1 kV side. It supplies 900 kVA load at 0.8 power factor lag from the 6.6 kV winding and 300 kVA load at 0.6 power factor lag from the 400 V winding. The RMS line current in ampere drawn by the 1.1 kV winding from the mains is _______.
Your input ____