1
GATE EE 2006
MCQ (Single Correct Answer)
+2
-0.6
A $$4$$ pole, $$50$$ $$Hz,$$ synchronous generator has $$48$$ slots in which a double layer winding is house. Each coil has $$10$$ turns and is short pitched by an angle to $$36$$ degrees electrical. The fundamental flux per pole is $$0.025$$ $$Wb$$

The line to line induced $$emf,$$ for two phase connection is

A
$$1143$$
B
$$1332$$
C
$$1617$$
D
$$1791$$
2
GATE EE 2006
MCQ (Single Correct Answer)
+1
-0.3
In a $$DC$$ machine, which of the following statements is true?
A
Compensating winding is used for neutralizing armature reaction while inter pole winding is used for producing residual flux.
B
Compensating winding is used for neutralizing armature reaction while inter pole winding is used for improving commutation.
C
Compensating winding is used of improving commutation while inter pole winding is used for neutralizing armature reaction.
D
Compensating winding is used for improving commutation while inter pole winding is used for producing residual flux .
3
GATE EE 2006
MCQ (Single Correct Answer)
+2
-0.6
A $$220V$$ $$DC$$ machine supplies $$20$$ $$A$$ at $$200V$$ as a generator. The armature resistance is $$0.2$$ ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by $$10\% ,$$ the ratio of motor speed to generator speed is
A
$$0.87$$
B
$$0.95$$
C
$$0.96$$
D
$$1.06$$
4
GATE EE 2006
MCQ (Single Correct Answer)
+1
-0.3
In transformers, which of the following statements is valid?
A
In an open circuit test, copper losses are obtained while in short circuit test, core losses are obtained.
B
In an open circuit test, current is drawn at high power factor.
C
In a short circuit test, current is drawn at zero power factor
D
In an open circuit test, current is drawn at low power factor.