1
GATE EE 2014 Set 2
Numerical
+2
-0
Two ammeters $$X$$ and $$Y$$ have resistances of $$1.2$$ $$\Omega $$ and $$1.5$$ $$\Omega $$ respectively and they give full-scale deflection with $$150$$ $$mA$$ and $$250$$ $$mA$$ respectively. The ranges have been extended by connecting shunts so as to give full scale deflection with $$15$$ $$A.$$ The ammeters along with shunts are connected in parallel and then placed in a circuit in which the total current flowing is $$15A.$$ The current in amperes indicated in ammeter $$X$$ is __________.
Your input ____
2
GATE EE 2014 Set 2
Numerical
+1
-0
While measuring power of a three-phase balanced load by the two-wattmeter method, the readings are $$100$$ $$W$$ and $$250$$ $$W$$. The power factor of the load is ___________.
Your input ____
3
GATE EE 2014 Set 2
MCQ (Single Correct Answer)
+2
-0.6
A $$20$$-pole alternator is having $$180$$ identical stator slots with $$6$$ conductors in each slot. All the coils of a phase are in series. If the coils are connected to realize single-phase winding, the generated voltage is $${V_1}.$$ If the coils are reconnected to realize three-phase star-connected winding, the generated phase voltage is $${V_ 2}.$$ Assuming full pitch, single-layer winding, the ratio $${V_1}/{V_2}$$ is
A
$${1 \over {\sqrt 3 }}$$
B
$${1 \over 2}$$
C
$${\sqrt 3 }$$
D
$$2$$
4
GATE EE 2014 Set 2
Numerical
+2
-0
There are two generators in a power system. No-load frequencies of the generators are $$51.5$$ $$Hz$$ and $$51$$ $$Hz,$$ respectively, and both are having droop constant of $$1$$ $$Hz/MW.$$ Total load in the system is $$2.5$$ $$MW.$$ Assuming that the generators are operating under their respective droop characteristics, the frequency of the power system in $$Hz$$ in the steady state is ____________.