1
GATE EE 2001
MCQ (Single Correct Answer)
+2
-0.6
A half-wave thyristor converter supplies a purely inductive load, as shown in figure. If the triggering angle of the thyristor is $${120^ \circ }$$, the extinction angle will be GATE EE 2001 Power Electronics - Single and Three Phase Rectifier Question 43 English
A
$${240^ \circ }$$
B
$${180^ \circ }$$
C
$${200^ \circ }$$
D
$${120^ \circ }$$
2
GATE EE 2001
MCQ (Single Correct Answer)
+2
-0.6
A $$50$$ Hz alternator is rated $$500$$ $$MVA,$$ $$20$$ $$kV,$$ with $${X_d} = 1.0$$ per unit and $$X'{'_d} = 0.2$$ per unit. It supplies a purely resistive load of $$400$$ $$MW$$ at $$20$$ $$kV.$$ The load is connected directly across the generator terminals when a symmetrical fault occurs at the load terminals. The initial rms current in the generator in per units is
A
$$7.22$$
B
$$6.4$$
C
$$3.22$$
D
$$2.2$$
3
GATE EE 2001
Subjective
+5
-0
A synchronous generator is connected to an infinite bus through a lossless double circuit transmission line. The generator is delivering 1.0 per unit power at a load angle of $${30^0}$$ when a sudden fault reduces the peak power that can be transmitted to 0.5 per unit. After clearance of fault, the peak power that can be transmitted becomes 1.5 per unit. Find the critical clearing angle.
4
GATE EE 2001
Subjective
+5
-0
A 132 kV transmission line AB is connected to a cable BC. The characteristic impedances of the overhead line and the cable are 400$$\Omega $$ and 80$$\Omega $$ respectively. Assume that these are purely resistive. A 250 kV switching surge travels from A to B.

(a) Calculate the value of this voltage surge when it first reaches C.

(b) Calculate the value of the reflected component of this surge when the first reflection reaches A.

(c) Calculate the surge current in the cable BC.