1
GATE EE 2001
MCQ (Single Correct Answer)
+2
-0.6
A $$100$$ $$\mu A$$ ammeter has an internal resistance of $$100\,\Omega $$. For extending its range to measure $$500$$ $$\mu A$$, the shunt required is of resistance (in $$\Omega $$)
A
$$20.0$$
B
$$22.22$$
C
$$25.0$$
D
$$50.0$$
2
GATE EE 2001
MCQ (Single Correct Answer)
+1
-0.3
The minimum number of wattmeter(s) required to measure 3 $$-$$ phase, 3 $$-$$ wire balanced or unbalanced power is
A
1
B
2
C
3
D
4
3
GATE EE 2001
Subjective
+5
-0
A $$50$$ $$kW$$ synchronous motor is tested by driving it by another motor. When the excitation is not switched on, the driving motor takes $$800$$ $$W.$$ When the armature is short-circuited and the rated armature current of $$10$$ $$A$$ is passed through it, the driving motor requires $$2500$$ $$W.$$ On open-circuiting the armature with rated excitation, the driving motor takes $$1800$$ $$W.$$ Calculate the efficiency of the synchronous motor at $$50\% $$ load. Neglect the losses in the driving motor.
4
GATE EE 2001
Subjective
+5
-0
Two identical synchronous generators, each of $$100$$ $$MVA,$$ are working in parallel supplying $$100$$ $$MVA$$ at $$0.8$$ lagging $$p.f.$$ at rated voltage. Initially the machines are sharing load equally. If the field current of first generator is reduced by $$5\% $$ and of the second generator increased by $$5\% ,$$ find the sharing of load ($$MW$$ and $$MVAR$$) between the generators.
Assume$${X_d} = {X_q} = 0.8\,\,p.u.$$ no field saturation and rated voltage across load. Reasonable approximations may be made.