1
GATE ME 1997
Subjective
+5
-0
In a certain double pipe heat exchanger hot water flows at a rate of $$50,000$$ $$kg/h$$ and gets cooled from $${95^ \circ }C$$ to $${65^ \circ }C$$. At the same time $$50,000$$ $$kg/h$$ of cooling water at $${30^ \circ }C$$ enters the heat exchanger. The flow conditions are such that the overall heat transfer coefficient remains constant at $$2270$$ $$W/{m^2}K$$. Calculate the heat transfer area required, assuming the two streams are in parallel flow, and for both the streams $${C_p} = 4.2\,\,kJ/kg\,\,K$$
2
GATE ME 1997
MCQ (Single Correct Answer)
+1
-0.3
Setup costs do not include
A
Labour cost of setting up machines
B
Ordering cost of raw material
C
Maintenance cost of the machines
D
Cost of processing the work piece
3
GATE ME 1997
MCQ (Single Correct Answer)
+1
-0.3
A dummy activity is used in $$PERT$$ network to describe
A
Precedence relationship
B
Necessary time delay
C
Resource restriction
D
Resource idleness
4
GATE ME 1997
Subjective
+5
-0
Determine the number of production runs and also the total incremental cost in a factory for the data given below: GATE ME 1997 Industrial Engineering - Inventory Control Question 7 English