1
GATE EE 2004
MCQ (Single Correct Answer)
+2
-0.6
A new generator having $${E_g} = 1.4\,\angle {30^ \circ }\,$$ pu [ equivalent to ($$1.212 +j$$ $$0.70$$)pu ] and synchronous reactance $$'{X_s}'$$ of $$1.0$$ pu on the system base, is to be connected to a bus having voltage $${V_t}$$ in the existing power system. This existing power system can be represented by Thevenin's voltage $${E_{th}} = 0.9\angle {0^ \circ }\,\,$$ pu in series with Tjhevenin's impedance $${Z_{th}} = 0.25\angle {90^ \circ }\,\,$$ pu. The magnitude of the voltage $${V_t},$$ of the system in pu will be
A
$$0.990$$
B
$$0.973$$
C
$$0.963$$
D
$$0.900$$
2
GATE EE 2004
MCQ (Single Correct Answer)
+1
-0.3
For harnessing low variable water heads, the suitable hydraulic turbine with high percentage of reaction and runner adjustable vanes is
A
Kaplan
B
Francis
C
Pelton
D
Impeller
3
GATE EE 2004
MCQ (Single Correct Answer)
+1
-0.3
In thermal power plants, the pressure in the working fluid cycle is developed by
A
Condenser
B
Super heater
C
Feed water pump
D
Turbine
4
GATE EE 2004
MCQ (Single Correct Answer)
+1
-0.3
The transmission line distance protection relay having the property of being inherently directional is
A
impedance relay
B
MHO relay
C
OHM relay
D
reactance relay