1
GATE EE 2004
MCQ (Single Correct Answer)
+2
-0.6
A single-phase, 230 V, 50 Hz, 4 pole, capacitor-start induction motor has the following stand still impedances
Main winding Zm =6.0 + j4.0Ω
Auxiliary winding Za = 8.0 + j6.0Ω
The value of the starting capacitor required to produce 90° phase difference between the currents in the main and auxiliary windings will be
A
176.84 µF
B
187.24 µF
C
265.26 µF
D
280.86 µF
2
GATE EE 2004
MCQ (Single Correct Answer)
+1
-0.3
For a linear electromagnetic circuit, the following statement is true.
A
Field energy is equal to the co-energy
B
Field energy is greater than the co-energy
C
Field energy is lesser than the co-energy
D
Co-energy is zero
3
GATE EE 2004
MCQ (Single Correct Answer)
+1
-0.3
The direction of rotation of a 3-phase induction motor is clockwise when it is supplied with 3-phase sinusoidal voltage having phase sequence A-B-C. For counter clockwise rotation of the motor, the phase sequence of the power supply should be
A
B-C-A
B
C-A-B
C
A-C-B
D
B-C-A or C-A-B
4
GATE EE 2004
MCQ (Single Correct Answer)
+1
-0.3
The type of single-phase induction motor having the highest power factor at full load is
A
shaded pole type
B
split-phase type
C
capacitor-start type
D
capacitor-run type