1
GATE EE 2004
MCQ (Single Correct Answer)
+2
-0.6
A 500 kVA, 3-phase transformer has iron loses of 300 W and full load copper losses of 600 W. The percentage load at which the transformer is expected to have maximum efficiency is
A
50.0%
B
70.7%
C
141.4%
D
200.0%
2
GATE EE 2004
MCQ (Single Correct Answer)
+2
-0.6
A 50 kVA, 3300/230 V single-phase transformers is connected as an autotransformer shown in figure. The nominal rating of the autotransformer will be GATE EE 2004 Electrical Machines - Transformers Question 54 English
A
50.0 kVA
B
53.5 kVA
C
717.4 kVA
D
767.4 kVA
3
GATE EE 2004
MCQ (Single Correct Answer)
+1
-0.3
The type of single-phase induction motor having the highest power factor at full load is
A
shaded pole type
B
split-phase type
C
capacitor-start type
D
capacitor-run type
4
GATE EE 2004
MCQ (Single Correct Answer)
+1
-0.3
The direction of rotation of a 3-phase induction motor is clockwise when it is supplied with 3-phase sinusoidal voltage having phase sequence A-B-C. For counter clockwise rotation of the motor, the phase sequence of the power supply should be
A
B-C-A
B
C-A-B
C
A-C-B
D
B-C-A or C-A-B