A forced commutated thyristorized step-down chopper is shown in the figure. Neglect the ON-state drop across the power devices. Assume that the capacitor is initially charged to 50 V with the polarity shown in the figure. The load current ($I_L$) can be assumed to be constant at 10 A. Initially, ThM is ON and ThA is OFF. The turn-off time available to ThM in microseconds, when ThA is triggered, is________ (rounded off to the nearest integer).
A single-phase half-controlled bridge converter supplies an inductive load with ripple free load current. The triggering angle of the converter is 60°. The ratio of the rms value of the fundamental component of the input current to the rms value of the total input current of the bridge is _________ (rounded off to 3 decimal places).
A single-phase full bridge voltage source inverter (VSI) feeds a purely inductive load. The inverter output voltage is a square wave in 180° conduction mode. The fundamental frequency of the output voltage is 50 Hz. If the DC input voltage of the inverter is 100 V and the value of the load inductance is 20 mH, the peak-to-peak load current in amperes is ________ (rounded off to the nearest integer).
In the DC-DC converter shown in the figure, the current through the inductor is continuous. The switching frequency is 500 Hz. The voltage ($V_o$) across the load is assumed to be constant and ripple free. The peak inductor current in amperes is __________ (rounded off to the nearest integer).