GATE EE 2017 Set 2
Numerical
+2
-0
A star-connected, 12.5 kW, 208 V (line), 3-phase, 60 Hz squirrel cage induction motor has following equivalent circuit parameters per phase referred to the stator. R1 = 0.3 Ω, R2 = 0.3 Ω, X1 = 0.41 Ω, X2 = 0.41 Ω. Neglect shunt branch in the equivalent circuit. The starting current (in Ampere) for this motor when connected to an 80 V (line), 20 Hz, 3- phase AC source is __________.
Your input ____
2
GATE EE 2017 Set 2
MCQ (Single Correct Answer)
+1
-0.3
If a synchronous motor is running at a leading power factor, its excitation induced voltage (Er) is
A
equal to terminal voltage Vt
B
higher than the terminal voltage Vt
C
less than terminal voltage Vt
D
dependent upon supply voltage Vt
3
GATE EE 2017 Set 2
Numerical
+2
-0
A $$3$$-phase, $$2$$-pole, $$50$$ $$Hz,$$ synchronous generator has a rating of $$250$$ $$MVA,$$ $$0.8$$ $$pf$$ lagging. The kinetic energy of the machine at synchronous speed is $$100$$ $$MJ.$$ The machine is running steadily at synchronous speed and delivering $$60$$ $$MW$$ power at a power angle of $$10$$ electrical degrees. If the load is suddenly removed, assuming the acceleration is constant for $$10$$ cycles, the value of the power angle after $$5$$ cycles is ________ electrical degrees.
Your input ____
4
GATE EE 2017 Set 2
Numerical
+2
-0
Two generating units rated $$300$$ $$MW$$ and $$400$$ $$MW$$ have governor speed regulation of $$6\% $$ and $$4\% $$ respectively from no load to full load. Both the generating units are operating in parallel to share a load of $$600$$ $$MW.$$ Assuming free governor action, the load shared by the larger unit is _______ $$MW.$$
Your input ____