1
GATE ME 1995
Subjective
+5
-0
A counter flow heat exchanger is to heat air entering at $${400^ \circ }C$$ with a flow rate of $$6$$ $$kg/s$$ by the exhaust gas entering at $${800^ \circ }C$$ with a flow rate of $$4$$ $$kg/s$$. The overall heat transfer coefficient is $${100^ \circ }C$$ $$W/\left( {{m^2}K} \right)$$ and the outlet temperature of the air is $${551.5^ \circ }C.$$ Specific heat at constant pressure for both air and the exhaust gas can be taken as $$1100$$ $$J/(kgK).$$ Calculate the heat transfer area needed and the number of transfer units.
2
GATE ME 1995
MCQ (Single Correct Answer)
+1
-0.3
If the demand for an item is doubled and the ordering cost halved, the economic order quantity
A
remains unchanged
B
increases by a factor of $$\sqrt 2 $$
C
is doubled
D
is halved
3
GATE ME 1995
Subjective
+5
-0
Consider the following data for a product:
Demand $$=1000$$ units/year
Order cost $$=$$ Rs.$$40$$/order
Holding cost $$ = 10\% $$ of the unit cost / unit-year
Unit cost $$=$$ Rs.$$500$$

(a) What is the economic order quantity?
(b) Under the $$EOQ$$ what is the number of annual orders?
(c) With a policy of ordering every month what would be the total annual cost as a percentage of the cost at $$EOQ$$?

4
GATE ME 1995
MCQ (Single Correct Answer)
+1
-0.3
In $$PERT,$$ the distribution of activity times is assumed to be
A
Normal
B
Gamma
C
Beta
D
Exponential