1
GATE EE 2022
MCQ (Single Correct Answer)
+1
-0.33

The most commonly used relay, for the protection of an alternator against loss of excitation, is

A
offset Mho relay.
B
over current relay.
C
differential relay.
D
Buchholz relay.
2
GATE EE 2022
MCQ (Single Correct Answer)
+1
-0.33

The geometric mean radius of a conductor, having four equal strands with each strand of radius r, as shown in the figure below, is

GATE EE 2022 Power System Analysis - Parameters and Performance of Transmission Lines Question 2 English

A
4r
B
1.414r
C
2r
D
1.723r
3
GATE EE 2022
MCQ (Single Correct Answer)
+1
-0.33

The valid positive, negative and zero sequence impedances (in p.u.), respectively, for a 220 kV, fully transported three-phase transmission line, from the given choices are

A
1.1, 0.15 and 0.08
B
0.15, 0.15 and 0.35
C
0.2, 0.2 and 0.2
D
0.1, 0.3 and 0.1
4
GATE EE 2022
Numerical
+1
-0.33
If only 5% of the supplied power to a cable reaches the output terminal, the power loss in the cable, in decibels, is ______. (round off to nearest integer).
Your input ____