1
GATE ME 1989
Subjective
+5
-0
The layout of a steam power plant working on the Rankine Cycle with single stage regeneration is shown in figure. Assuming the exit stream from the re-generator to be saturated draw the corresponding ideal cycle on a Mollier Chart and derive an expression for the thermal efficiency of the cycle. GATE ME 1989 Thermodynamics - Rankine Cycle Question 1 English

Boiler $$-$$ $$B$$
Feed water heater $$-R$$
Pump $$-P$$