1
GATE EE 1997
MCQ (Single Correct Answer)
+1
-0.3
If an induction machine is run at above synchronous speed, it acts as
A
a synchronous motor
B
an induction generator
C
an induction motor
D
none of the above
2
GATE EE 1997
Fill in the Blanks
+2
-0
A single-phase alternator has a synchronous reactance of $$2$$ $$ohms$$ and negligible resistance. If it supplies $$10$$ $$A$$ to a purely capacitive load at $$200V,$$ then generated $$e.m.f$$ will be ... $$V$$ and the regulation will be ...... $$\% $$
3
GATE EE 1997
Subjective
+5
-0
A $$5MVA$$, $$11kV$$, $$3$$-phase star connected alternator is synchronized to the bus bars and is operating with an induced $$EMF$$ of $$125\% $$ of the rated voltage. If the load current is $$500$$ $$A,$$ what is the power factor of operation? The machine has a synchronous reactance of $$5\,\,\Omega $$ and negligible resistance per phase.
4
GATE EE 1997
Numerical
+5
-0
A $$200V$$, $$10$$ $$kW$$ lap-wound $$d.c.$$ generator has $$10$$ poles and $$500$$ conductors on it's armature. If the pole face covers $$80\% $$ of the pole pitch, the pole face conductors required to fully compensate for armature reaction will be ___________________ conductors/pole.