Thysistor circuits that directly convert poly phase $$ac$$ voltage from one frequency to another frequency are called _______.
2
GATE EE 1994
True or False
+2
-0
The charging current of a $$400$$ kV transmission line is more than that of a $$220$$ kV line of the same length.
A
TRUE
B
FALSE
3
GATE EE 1994
MCQ (Single Correct Answer)
+1
-0.3
In a $$400$$ kV network, $$360$$ kV is recorded at a $$400$$ kV bus. The reactive power absorbed by a shunt reactor rated for $$50$$ MVAR, $$400$$ kV connected at the bus is
A
$$61.73$$ MVAR
B
$$55.56$$ MVAR
C
$$45$$ MVAR
D
$$40.5$$ MVAR
4
GATE EE 1994
MCQ (Single Correct Answer)
+2
-0.6
Consider a three-phase, $$50$$ $$Hz$$, $$11$$ $$kV$$ distribution system. Each of the conductors is suspended by an insulator string having two identical porcelain insulators. The self capacitance of the insulator is $$5$$ times shunt capacitance. The voltage drop across botton most disc is:
A
$$3.46$$ $$kV$$
B
$$34.6$$ $$kV$$
C
$$346$$ $$kV$$
D
None